Fixed-flow regulator preset to 0.5 LPM fitted to a calibration gas cylinder
Calibration Gases · Gas Regulators

Fixed-Flow Regulator

The Fixed-Flow Regulator supplies calibration gas at a factory-preset, constant rate for diffusion-type gas detectors. With no user adjustment required, it removes flow-setting errors and speeds routine bump testing and calibration. Engineered for reliable repeatability, it delivers a steady stream that matches the sampling behaviour of passive sensors across GCC and Indian industrial sites.

Preset 0.5 LPMNo adjustmentDiffusion detectors
Genuine products · Technical support · Fast delivery across India & the GCC

Product Description

The Fixed-Flow Regulator is purpose-built for the calibration and bump testing of diffusion-based gas detection instruments that draw gas passively rather than by pump. Preset at the factory to a constant delivery rate, typically 0.5 litres per minute, it eliminates the guesswork and human error associated with manually adjusted devices. Technicians simply attach the regulator to a threaded calibration gas cylinder, connect the tubing, and apply gas at a rate the instrument recognises as representative of ambient exposure. The sealed preset mechanism holds output steady from a full cylinder down to near-depletion, protecting the integrity of every calibration record.

Constructed from corrosion-resistant materials suited to reactive and non-reactive gas mixtures, the regulator provides consistent, repeatable performance in workshops, control rooms and remote field locations alike. Its compact, lightweight body makes it ideal for portable calibration kits used across oil and gas terminals, petrochemical plants and utility sites throughout the GCC and India. Because the flow rate cannot drift or be accidentally altered, maintenance teams achieve dependable results while satisfying stringent safety and audit requirements. Filosha Industrial supplies these regulators with cylinder connections matched to common gas standards, backed by responsive regional stock and technical support to keep detector fleets compliant and ready.

Key Features

  • Factory-preset constant output of approximately 0.5 LPM for diffusion detectors
  • Sealed, tamper-resistant flow mechanism prevents accidental adjustment
  • Stable delivery maintained from full cylinder to near-depletion
  • Corrosion-resistant body compatible with reactive and inert gas blends
  • Standard cylinder thread for quick, secure attachment
  • Compact, lightweight design suited to portable calibration kits

Applications

  • Routine bump testing of passive diffusion gas detectors
  • Span calibration of fixed and portable monitors
  • Field verification at remote and unmanned installations
  • Workshop and calibration-bench servicing programmes
  • Pre-shift instrument checks in confined-space work
  • Compliance and audit-driven detector maintenance

Benefits

  • Removes flow-setting errors for consistent, auditable results
  • Speeds routine bump tests and reduces technician training needs
  • Protects calibration integrity with drift-free constant output
  • Lowers gas waste through a matched, controlled delivery rate

Technical Highlights

  • Preset flow tolerance held across full cylinder pressure range
  • Materials selected for compatibility with corrosive gas species
  • Precision orifice designed for passive-sampling detectors
  • Robust sealing for leak-free connection and storage

Industries Served

Oil & GasPetrochemicalChemicalManufacturingPower & UtilitiesMarine & Offshore

Specifications

Flow TypeFixed / factory-preset
Typical Flow Rate0.5 LPM
Detector CompatibilityDiffusion / passive sampling
Cylinder ConnectionStandard C10 / equivalent thread
Body MaterialCorrosion-resistant alloy
AdjustmentNone (sealed)
Operating Temperature-10 to 50 degrees C

Specifications are indicative. Contact us for full technical data, datasheets and available variants.

Related Products

Variable FlowAdjustable Flow Regulator

Adjustable Flow Regulator

Variable-flow regulator with indicator delivering 0.1 to 6 LPM for diverse detection instruments.

  • 0.1 to 6 LPM
  • Flow indicator
  • Multi-instrument
View Details
Demand FlowDemand-Flow Regulator

Demand-Flow Regulator

Demand-flow regulator releasing gas only when drawn by a pumped detector, eliminating waste.

  • On-demand delivery
  • Zero waste
  • Pumped detectors
View Details
Gas TubingCalibration Gas Tubing

Calibration Gas Tubing

Inert PTFE, Tygon and PVC tubing matched to reactive or non-reactive calibration gases.

  • PTFE / Tygon / PVC
  • Reactive-gas ready
  • Low adsorption
View Details
Pressure ControlPressure Regulator

Pressure Regulator

Single or dual-stage pressure regulator for high-pressure refillable calibration gas cylinders.

  • Single/dual stage
  • High-pressure cylinders
  • Refillable
View Details

Need a Quote or More Information?

Tell us your requirement and our team will respond with pricing and technical details.

Request a Quote