PTFE, Tygon and PVC calibration gas tubing for reactive and non-reactive gases
Calibration Gases · Calibration Accessories

Calibration Gas Tubing

Calibration Gas Tubing connects regulators to detectors without compromising sample integrity. Available in inert PTFE for reactive gases and flexible Tygon or PVC for non-reactive mixtures, it resists adsorption and permeation to ensure accurate delivery. Correct tubing selection is essential for reliable calibration across GCC and Indian gas detection programmes.

PTFE / Tygon / PVCReactive-gas readyLow adsorption
Genuine products · Technical support · Fast delivery across India & the GCC

Product Description

Calibration Gas Tubing is the critical link between the regulator and the instrument under test, and the choice of material directly affects calibration accuracy. Reactive gases such as hydrogen sulphide, chlorine and other adsorptive species require chemically inert PTFE tubing, which resists absorption and permeation so that the concentration reaching the sensor matches the certified cylinder value. For non-reactive gases such as methane, carbon dioxide and oxygen mixtures, flexible Tygon or PVC tubing offers an economical and easy-to-handle alternative. Using the wrong tubing can cause reactive gas to be lost to the tube wall, producing false low readings and unreliable calibrations.

Selecting the correct grade therefore protects both the accuracy of the result and the confidence of any subsequent audit. The tubing is supplied with a consistent internal bore that promotes stable, predictable flow and connects readily to standard regulator outlets and detector inlets, making it simple to assemble portable kits or plumb fixed calibration benches. Its clean inner surface minimises the memory effects that can carry contamination between successive tests, which is especially important when moving between different gas concentrations. Suited to oil and gas terminals, petrochemical plants, chemical works, water treatment sites and general manufacturing across the GCC and India, the range covers both reactive and non-reactive needs. Filosha Industrial supplies calibration gas tubing in cut lengths and continuous rolls with a choice of diameters, backed by regional stock and technical guidance, so maintenance teams can match tubing to gas type and achieve accurate, repeatable calibration every time.

Key Features

  • Inert PTFE tubing for reactive and adsorptive gases
  • Flexible Tygon and PVC options for non-reactive mixtures
  • Low adsorption and permeation preserves gas concentration
  • Consistent bore for stable, predictable flow
  • Compatible with standard regulator and detector fittings
  • Available in cut lengths and continuous rolls

Applications

  • Connecting regulators to gas detectors during calibration
  • Reactive-gas delivery requiring inert tubing
  • Non-reactive span-gas connections
  • Portable calibration kit assembly
  • Bench and gas-panel plumbing
  • Multi-point calibration and manifold links

Benefits

  • Preserves gas concentration for accurate results
  • Material choice matched to gas reactivity
  • Reduces false low readings from wall adsorption
  • Economical options for non-reactive applications

Technical Highlights

  • PTFE bore inert to corrosive and reactive species
  • Low-permeation walls maintain sample integrity
  • Uniform internal diameter for consistent flow
  • Flexible grades rated for repeated field handling

Industries Served

Oil & GasPetrochemicalChemicalWater & WastewaterManufacturingPower & Utilities

Specifications

MaterialsPTFE, Tygon, PVC
Reactive-Gas GradePTFE (inert)
Non-Reactive GradeTygon / PVC
Internal DiameterTypically 3 to 6 mm
Supply FormCut lengths and rolls
Key PropertyLow adsorption and permeation
Operating Temperature-10 to 60 degrees C

Specifications are indicative. Contact us for full technical data, datasheets and available variants.

Related Products

Constant FlowFixed-Flow Regulator

Fixed-Flow Regulator

Factory-preset constant-flow regulator delivering a fixed 0.5 LPM for diffusion gas detectors.

  • Preset 0.5 LPM
  • No adjustment
  • Diffusion detectors
View Details
Variable FlowAdjustable Flow Regulator

Adjustable Flow Regulator

Variable-flow regulator with indicator delivering 0.1 to 6 LPM for diverse detection instruments.

  • 0.1 to 6 LPM
  • Flow indicator
  • Multi-instrument
View Details
Sampling BagGas Sampling Bag

Gas Sampling Bag

Inert sampling bag for collecting grab, flue and stack gas samples reliably.

  • Inert film
  • Grab / flue / stack
  • Leak-tight valve
View Details
Field CaseCalibration Gas Carry Case

Calibration Gas Carry Case

Protective case holding cylinders, regulator and detector for organised field calibration.

  • Cylinder storage
  • Impact-resistant
  • Field-ready
View Details

Need a Quote or More Information?

Tell us your requirement and our team will respond with pricing and technical details.

Request a Quote